Skip to main content

Meshnology N37 Wio Tracker L1

1. Overview

  • Product: Meshnology N37 - Seeed Wio Tracker L1 LoRa Meshtastic GPS Development Board, equipped with a 1.3″ OLED display.
  • Positioning: Used for Meshtastic nodes, LoRa Mesh networks, GPS tracking, IoT prototyping, etc.
  • Features: Pre-installed with Meshtastic firmware, easy to use out of the box, supports multiple power supply methods (USB-C, solar power, Li-ion battery), compatible with Grove extensions.

1.1 Product Description

  • Main functions
    • Integrated Nordic nRF52840 MCU (64 MHz)
    • LoRa SX1262 Wireless Module (862‑930 MHz)
    • High-precision GNSS Module (GPS, BeiDou, GLONASS, QZSS)
    • OLED Display (1.3″ 128×64)
    • Bluetooth 5.0 Support
    • Grove Interface, Debug SWD Pins

1.2 Specifications

Parameter CategoryDetails
MCUNordic nRF52840 ARM Cortex‑M4
Flash / RAM1 MB Flash, 256 KB RAM
LoRaWio‑SX1262, 862‑930 MHz
GNSSL76K (GPS/BeiDou/GLONASS/QZSS)
Display1.3″ OLED 128×64
InterfaceGrove, UART/I2C/GPIO, SWD
Power SupplyUSB‑C, Solar 5 V/1 A, Li‑ion 3.7 V
CertificationsFCC, CE, RoHS

2. Hardware Details

2.1 Pin description

img

img

2.2 Grove and peripheral expansion

The usage method of the Grove interface and the list of pluggable sensors.

You can add sensors to the device through the Grove interface. The following sensors have been verified to be compatible with the Grove interface on the device.

Sensor TypeSensor Model
Environmental sensorPressureBMP085
TemperatureMCP9808、PCT2075
Temperature and humiditySHT31 /SHTC3 / SHT4X、AHT10
Temperature,humidity, and air pressureBME280
OtherHeart rate and blood oxygen saturationMAX30102
I2C keyboradCardKB

3. Getting Started

3.1 Packing List

  • Wio Tracker L1 System Board

  • LoRa antenna

  • GPS module

  • 3000 mAh battery

  • N37 3D shell

3.2 First Use(Basic Steps)

Note: When the device displays the following status, please do not manually restart or shut down the device. Otherwise, the device may be damaged.

  1. Message transmission process is not completed
  2. In the process of configuration

Flash firmware

Please don't use NRF-OTA to update the firmware, as it may cause the device to completely fail to start.

Visit Meshtastic Web Flasher.

For L1, L1 Lite, and L1 Pro, select the target device as Seeed Wio Tracker L1 and choose the latest firmware, then click Flash.

img

img

For L1 E-Ink, select the target device as Seeed Wio Tracker L1 E-Ink and choose the latest firmware, then click Flash.

img

img

Open it, click Enter DFU Mode, and a device named Tracker L1 will appear. Click on it and connect to it. A drive named Tracker L1 should be displayed.

img

Drag the UF2 file to the DFU drive. After the file download is complete, the firmware should be flashed, and the device will restart.

3.3 Connect Meshtastic App

Start

Connect the USB cable to activate the device. Flick the power switch upwards to turn it on.

❗Prompt

If the device does not respond when you press the button, please charge it first. Do not use a fast-charging charger.

Through application

iOS application

  • Select the target device on the Bluetooth panel.

img

  • Input the code displayed on the screen, and then click OK to connect the device.

img

  • Android app

  • Click + and select the target device.

img

  • Input the code (the default code is 123456), and then click OK to connect the device.

img

Through the website

If you wish to send text messages and communicate with other nodes on the website, you can now connect your device to the Meshtastic website.

Step 1: Open the website

clickGo to this website.

img

Step 2: Add a new device

Click "+ New Connection".

img

There are two connection methods. You can choose the one you prefer.

Method 1: Via Bluetooth

Select the Bluetooth method. Choose the device ID in the pop-up window.

img

Method 2: Through serial port

Select the serial port mode. Open the Device Manager to check which port the device is connected to. Select that port in the pop-up window.

img

Your device will be displayed in the list. Click to connect. If the connection is successful, you can directly view the device status on the website.

img

Configuration

In order to start communicating through the mesh, you must set the region. This setting controls the frequency range used by your device and should be set according to your fault.

iOS application

img

Android application

img

Now that you have set up the LoRa region on your device, you can proceed to configure any LoRa settings to meet your specific needs.

Configure GPS

Please enable GPS. You can adjust the update interval and broadcast interval to obtain more timely location information.

img

For iOS, please enable Accurate Location. Otherwise, there may be deviations in location determination.

img

**6.**Firmware & Code

Videos & Media

📺 Tutorials and Demonstration Videos:

https://www.youtube.com/watch?v=6E4dY-J4Jb4

📺 Practical Demonstration and Operation:

https://www.youtube.com/watch?v=mzcdMKscX6M&t=253s

Frequently Asked Questions and Support (FAQ & Support)

Device bricking and bootloader installation

Description:

The device is not responding, there is no LED, and it cannot be paired with your application. If you find that the device completely freezes after flashing its own firmware, you can also try reinstalling the bootloader.

note

When flashing the bootloader, please ensure that the cable connection is stable and do not disconnect it during the flashing process.

  • Step 1: Click here to download the bootloader

  • Step 2: Enter DFU mode

    Double-click the RST button to enter DFU mode. The disk name "Tracker L1" will pop up.

    img

  • Step 3: Paste the bootloader file

    Overwrite all files on the disk with the downloaded bootloader file.

  • Step 4: Flash firmware

After completing the aforementioned steps, you can flash the application firmware. You may need to manually enter DFU mode

Unable to enter DFU and manually enter DFU mode

Connect the device to your PC and double-click the Reset button. The yellow LED will remain continuously lit, and a new USB drive named Tracker L1 will appear on your PC.

Exit DFU mode

Press the Reset button once to exit DFU mode.

Automatic device shutdown

Description

  • After the device is turned on, it will automatically shut down or restart after a period of time.
  • The serial port log stops after running for a period of time.

This may be caused by manually forcing a restart or shutdown of the device when it is in the following states: unfinished message transmission process, or in the process of configuration .....

Troubleshooting

Click here to watch the video. You need to perform a flash erase and then re-flash the latest firmware.

Restore factory settings

If you wish to revert to the default settings, you can perform a factory reset. There are two methods to perform a factory reset.

  • Click here to watch the video. You need to perform a flash erase and then re-flash the latest firmware.
  • Click the Factory Reset button in the app. The device will automatically restart using its factory settings.

img

Signal quality

  • SNR reflects the quality of the communication link. Normal devices usually operate above -7 dB. Devices with SNR below -10 dB indicate poor performance.
  • RSSI is determined by both the device and its surrounding environment. Normal devices typically operate above -110 dBm. Devices with RSSI below -115 dBm are considered to have poor performance.

To achieve the best signal effect, please use the device in an open, unobstructed area with minimal interference.

Compatible Antennas

If you need to replace the antenna for Meshnology N37, click here to obtain one.

If you need to obtain the complete kit of Meshnology N37, click here to acquire one.